My Account Home
$5.2B Global Marketplace for Asset Recovery & Surplus Inventory

Categories

Manufacturers

All Listings > Oil and Gas > Downstream Oil & Gas > Atmospheric Fired Heater

Atmospheric Fired Heater

PLACE A BID
Mouse over to Zoom
-
Click to enlarge
ID: 182999447
Quantity: 1 ea
Condition:

All the items are "as is, where is". Buyer is responsible for loading, freight and logistics to final destination.

# of Bids: 0 PLACE A BID
Product Location: South America
End Time: Bid As Soon As Possible
Time Remaining: Bid As Soon As Possible
Trader: Carolina Acosta   +1-832-239-5361ASK A QUESTION

Seller Description

This  ATMOSPHERIC FIRED HEATER is no longer needed for the company's own operation and is being sold as an asset liquidation for its owner.

Details are listed below:

Item   B-1     (Note 1) CASE 25º API CRUDE CHARGE  
Coil nº           NORMAL OPERATING CONDITION
Service ATMOSPHERIC FIRED HEATER        
Handled fluid 25º API CRUDE BLEND          
Max. thermal flux in radiant section   kcal/hm² 32500 (Note 2)  
Max. thermal flux in convective section   kcal/hm²      
Total absorbed heat       (Note 5) MMkcal/h 25.37 + 0.94 (by crude + steam coil)
Minimum efficiency on L H V       % (Note 4)    
                   
               Input Stream     Output Stream 
Total flow of handled fluid       kg/h 304045   304045
Vapor flow rate in / out         kg/h 0   112760
Liquid flow rate in / out         kg/h 304045   191285
Percentage of vaporized fluid in / out   % 0   37.1
Steam flow rate          kg/h (Note 7)    
Liquid spec. gravity in / out         0.677   0.723
Liquid viscosity in / out         cP 0.242   0.309
Liquid enthalpy in / out         kcal/kg -299.5   -214.4
Vapor enthalpy in / out         kcal/kg     -219.0
                   
Temperature in / out         ºC 280   382
Inlet / Outlet pressure         kg/cm2g 13,4 max.   1.83
Max. allow. pressure drop       kg/cm2 (Note 4)    
                   
Design pressure         kg/cm2 16   (Note 4)
Tubes material           9% Cr  1% Mo   (Note 4)
Velocity of corrosion per year       mm/year      
Coke formation expected              
Conections (bends or headers)            
Pipe diameter in           (Note 4)    
Pipe diameter out           (Note 4)    
                   
Burners type           (Note 4)    
Fuel             Diesel Oil   Fuel Gas
              (&)   (&)
Specific gravity           0.842    
Molecular Weight         kg/kmol     22.3
Low Heating Value         kcal/kg 10222   10597 kcal/m3
Temperature at burner         ºC 20   30
Pressure at the header / burner     kg/cm2g 6.0   4.8 / 1.5
Viscosity at 40ºC         cP 2.6    
Sulfur           0.005 w%   100 mg/m3 max.
Vanadium         wppm 1    
Atomization steam pressure       kg/cm2 10.5    
External air temperature       ºC 15    
                   

 

FIRED HEATERS PROCESS DATASHEET            
                     
Item   B-1     (Note 1)          
Coil nº                  
Service ATMOSPHERIC FIRED HEATER          
Handled fluid 26º API CRUDE / 30º API CRUDE          
                     
                     
  FUEL GAS COMPOSITION              
                     
                     
  Natural Gas   Normal (average *)  
  Component %   Component %  
  H2O     H2S 0.073  
  O2     H2 30.444  
  N2 0.81   O2 0.045  
  CO     N2 2.331  
  CO2 1.48   CO 0.295  
  H2S 6 mg/m3   CO2 0.391  
  H2     Methane 31.412  
  Methane 92.35   Ethane 8.797  
  Ethene     Ethilene 2.454  
  Ethane 4.18   Propane 8.585  
  Propene     Propilene 2.083  
  Propane 0.73   Isobutane 4.026  
  Butenes     n-Butane 3.359  
  i-Butane 0.12   t-butene 1.242  
  n-Butane 0.19   1-butene 1.104  
  Pentenes     isobutene 1.565  
  i-Pentane 0.05   cis-butene 0.720  
  n-Pentane 0.05   1,3-butadiene 0.063  
  n-hexane 0.04   Isopentane 0.499  
  RSH 23 mg/m3   n-pentane 0.140  
  S Total 100 mg/m3   Hexane + 0.380  
  Total Composition 100   Total Comp. 100.009  
                     
            * average percent values for each component  
            calculated from database informed by ERBB  
            with values from 31/Aug/2004 to 28/Jun/2007,  
            (mail RRE.OP23-ERBB-TR-010 dated 12/07/07)  

Seller Terms

  • Salvex and the seller have the right to reject any and all offers.
  • This product is sold AS IS, WHERE IS.
  • Buyer is responsible for all taxes, duties, loading and freight charges.
  • Seller does not offer any warranties or manufacturer warranties.
  • Upon receipt of cleared funds, Seller will provide the Buyer a Release Order for item pick up. Title transfers from Seller to Buyer upon issuance of the Release Order.
  • It is Buyer's responsibility to verify quantities and condition at the time of pick up. Once the product has been removed from Seller's location, there will be no adjustments based on quantity or condition.
PLACE A BID

Other Listings in Downstream Oil & Gas

(0 bids)
2 Oxidation Reactors
Pennsylvania, United States
(2 bids)
25 Cellars
Pennsylvania, United States
(0 bids)
4 Units
null, United States
(0 bids)
1 Head
West Virginia, United States

Atmospheric Fired Heater


Downstream Oil & Gas

(0 bids)
1 ea
South America
(12 bids)
1 Control Skid
Texas, United States
(0 bids)
1 Unit
Texas, United States
(0 bids)
1 Unit
Pakistan
(0 bids)
1 Unit
Texas, United States
(0 bids)
5 Filters
Pennsylvania, United States
(5 bids)
4 VFD
Oklahoma, United States
(0 bids)
2 LACT
United States
VIEW ALL DOWNSTREAM OIL & GAS LISTINGS (12)

Other Listings in Oil and Gas

(4 bids)
17 Unit
Texas, United States
(0 bids)
1 Unit
North America

BH-1500 Mobile Storage Tanks (3 Tanks)


Fracking Equipment and Supplies

(2 bids)
3 Tanks
United States
(1 bids)
441.27 Feet
Asia-Pacific

500-Barrel Frac Tanks (15 Units )


Fracking Equipment and Supplies

(10 bids)
15 Unit
Oklahoma, United States
(0 bids)
1 Unit
United States
End Date: Oct-20-21 09:55 AM CST
(1 bids)
920 Feet
null, India
(3 bids)
202 Units
India
(2 bids)
5344.4571 Feet
Middle East
(0 bids)
27 UNITS
Middle East
(4 bids)
2 Units
null, Slovenia
(0 bids)
1 Unit
North America
(3 bids)
354 Joints
Africa
VIEW ALL OIL AND GAS LISTINGS (1226)