$5.2B Global Marketplace for Asset Recovery & Surplus Inventory

    Attention

    This item is no longer available.

    CT Scanner Equipment - U-SPECT(7) / CT(HR) / OI(FLT) / E-Class - Damaged (1 Unit)

    Attention

    This item is no longer available.

    CT Scanner Equipment - U-SPECT(7) / CT(HR) / OI(FLT) / E-Class - Damaged (1 Unit) Share with Buyers


    ID:183050899
    Seller:
    Seller Industry:
    Quantity:1 Unit
    Manufacturer:

    Unknown View more items from this manufacturer

    Condition:
    Insurance Claim Damaged

    Structural Damage: " The back loader (tube and holder for SPECT collimators) was under high tension and could not be re-fitted, indicating deformation of the SPECT frame gantry. " Deformation of the full frame gantry and interior, with deformed sheet metal covers and dents. Please refer to Image #10. " Multiple snapped bolts with broken ends stuck in tapered holes. " Misalignment and deformation of gamma detectors and the XYZT stage. " Snapped bolts holding the CT door and damage to the X-ray CT scanner. Please refer to image #14. " Deformed aluminum casing with lead sheets for shielding. " Broken off CT gantry and rotation stage. Please refer to image #13. " Cut cables between the X-ray CT module and main frame. " Shattered outside cover panels.

     

    Component Damage: " Gamma detectors with potential cracks in crystal plates and compromised vacuum seals. " X-ray source with possible cracks in the Beryllium window. " Snapped parts inside the CT gantry affecting the high precision gantry and linear stage. § Other Damage: " Potential cracks in electronic PCBs and desoldered components. " Pulled cables and tubing affecting connections and couplings.

     

    Salvageable Items: Ø Optical module with docking station Ø Collimators (i.e. GP-M, UHR-RM) Ø Gas anesthesia system and carbon filter Ø System touchscreen Ø Animal monitoring laptop Ø All animal beds Ø Bottom covers (they were taken off before packing and put in another crate)


    :
    Product Location:
    End Time:

    Item Description

    This lot of CT Scanner Equipment - U-SPECT(7) / CT(HR) / OI(FLT) / E-Class was involved in an insurance claim and is being sold by the insurance company to recover funds from the loss.

    System Type: U-SPECT(7) / CT(HR) / OI(FLT) / E-Class

    Configuration:

    • E-Class U-SPECT with two M5 collimators
    • GP-M
    • UHR-RM
    • CT HR
    • Animal heating module
    • Gas anesthesia system
    • Cardiac and respiratory monitoring and gating package
    • Multi-mouse bed (ø60 mm) with gas anesthesia and heater mat including temperature control and heating
    • OI module with docking station and various beds and filters
      • Beds:
        • 3-mouse bed
        • 5-mouse bed
    • Excitation filters:
      • 472-30; 500-24; 527-20; 543-22;
      • 572-28; 586-20; 605-15; 625-15;
      • 640-14; 661-20; 710-40
    • Emmission filters:
      • 520-36; 586-20; 615-20;
      • 631-21; 661-20; 775-46

    Seller Terms

    • Salvex and the seller have the right to reject any and all offers.
    • This product is sold AS IS, WHERE IS.
    • Buyer is responsible for all taxes, duties, loading and freight charges.
    • Seller does not offer any warranties or manufacturer warranties.
    • Upon receipt of cleared funds, Seller will provide the Buyer a Release Order for item pick up. Title transfers from Seller to Buyer upon issuance of the Release Order.
    • It is Buyer's responsibility to verify quantities and condition at the time of pick up. Once the product has been removed from Seller's location, there will be no adjustments based on quantity or condition.

    Salvex handles surplus, bankruptcy, overruns, obsolete inventory, disposal, insurance claims, online auctions, liquidation sale, foreclosure, lockout, seized, scrap, salvage, new, used, damaged, refurbished, and asset recovery.

    Repurposing commercial assets creates carbon offsets and sustainability corporate solutions.