    These unused 3 Mud Logging Units are sold as an asset recovery for its owner.

    They can also be sold individually.

    All items are sold  As Is, Where Is. The buyer is responsible for handling and transport.


    :
    Product Location:
    End Time:

    Item Description

     Mud Logging Unit Technical Specification

     Content

    The specification required WELLSTAR® Mud Logging Unit (hereinafter referred to as unit) requirements, test methods, test rules, signs, packaging, transportation and storage. This specification is suitable for equipment manufactory and quality value

    Criterion document

    The provisions of the following documents through the use of this standard become the standard clauses. Note that the dates cited documents, all subsequent changes (not including the contents Corrigendum), or Rev. Standards do not apply to this, however, encourage the parties to reach an agreement under this standard whether can be used to study the latest edition of documents. All of the cited documents do not note the date, applicable to the latest edition of the standard. 

    Demand 

    3.1 Working Condition

    a) Environment temperature:  -40 ~ 60;

    b) Room temperature: 0 ~ 30; 

    c) Room humidity:  ≤80%.

    3.2 Power 

    a) Voltage Input: 3-phase 220V380V440V, Frequency range 45~60Hz;

    b) Voltage Output: 3-phase 380V, single 110V(220V)±20%, owern20Kw; 

    c) UPS output : 220V±5%, 0±1Hz, error<5%,cntinue ≥30min

    3.3 Insulation 

    a) At working condition,Coat a piece of the power circuit of the electrical insulation on the device >2M&; 

    b) Devices should be installed electricity overload protection and grounding line column. 

    3.4 Cabin and safety system 

    •  Cabin shell structure container equipment used to suppress the fire-explosion. 1 level in the region (including offshore drilling platforms) & obtaining certification.
    • Size:  8500×2591×2591mminclude pry of length 8920mm Total weight: 13T
    • Safe system 
    • Inner Air pressure keeps 50Pa~150Pa, Alarming at less than 50Pa, automatic alarm and main power shutdown.
    • Combustibility gas test. Testing range: 0~100%LE Accuracy±2%. hen the concentration of flammable gas explosion limit the scope 20%~5%LE it is alarm; When the concentration of flammable gas explosion at the minimum 50%LE should cut off the main power supply and fan power.
    • Fog detection, Alarm, testing Range: 0~100%SF. Accuracy:±2%, larming range: >20%SF main power shutdown.
    • Emergency lighting, lighting time 30 minutes.
    • Equipment room should have the necessary facilities, guarantee equipment  can contradict impact shocked and bump. Cable channel with MCT.
    • Room noise: o60dB.
    • Load & Transportation. 

    3.5 Appearance 

    • Cabin and equipment should be no obvious drawback , the installation of fastening parts, the panel notes should be clear and correct function symbols.                                                                             

     3.6 Gas analysis parameter 

    • Natural gas full measurement test
    • Measure parameter: hydrocarbon
    • Measure elements:FID
    • Measure method:continuum
    • Sensitivity:less than 10ppm methane)
    • Measurement Range:10ppm ~100%&nsp;
    • High 100?;8000±500mV
    • Base line drift:per hour < ±0.1mV
    • Noise : <0.05 mVrecord
    • Repeat error: <±5%

    3.7 Natural gas GH testing 

    • Measure content: C1,C2, C3, IC4, IC5, NC5
    • Detection Method:FID 
    • Test method:cycle 
    • Analyze cycle: 30~90S 
    • Sensitivity: 10ppmmethane
    • Examine range: 10ppm~100%
    • column chromatographic separate  methane, ethane separation better than 0.90
    • Base line driftper hour< ±0.1mV 
    •  Noise: <0.05 mVrecord
    • Repeat error<±5%

    3.8 CO2  Detector 

    • Analyze Method: continuum analyze
    • Sensitivity:  1000ppm 
    • Test range:  1000ppm~100%
    • Repeat error: <±5%
    • Base line drift:  1%F /7d 
    • Noise:  <1000×10-6 ppm

     H2S testing 

    • Test range:  0~100ppm
    • Accuracy : ±2ppm

    3.7 PT parameter

    •  Hook Height(CPS-JC-04)
    • Built in P F inductive pick-up 
    • Working voltage: 8VDC,80 pulse/round 
    • Switching frequency ≤2000 HZ 
    • Measurement: 0~50m
    • Accuracy : single ±1%
    • Output signal: pluse signal(4 wire), high level>3.5VDE,low level<0.75VDC 
    • Working temperature: -45~ 100
    •  Hook load/Weight on Bit(CPS-XZ-04) 
    • Working voltage: 24VDC 
    • Measurement: 0~7Mpa
    • Accuracy : ±0.25%FS/li>
    • Sensitivity: ±0.25%FSnbsp;
    • Error: ±2%FSnbsp;
    • Output signal: 4~20Ma(2 wire)
    • Working temperature: -45~ 100
    • Mechnical torque sensor(CPS-XZ-04)
    • Working voltage: 24VDC 
    • Measurement: 0~7Mpa
    • Accuracy : ±0.25%FS/li>
    • Sensitivity: ±0.25%FSnbsp;
    • Error: ±2%FSnbsp;
    • Output signal: 4~20Ma(2 wire)
    • Working temperature: -45~ 100
    • Electrical torque sensor(CPS-NJE-01)
    • Working voltage: 24VDC 
    • Measurement: 0~1000A
    • Accuracy : ±2%FS/li>
    • Sensitivity:  2%FSnbsp;
    • Error: ±2.5%FSnbsp;
    • Output signal: 4~20Ma(2 wire) 
    • Working temperature: -45~ 70 3.7.5 Stand pipe pressure sensor(CPS-LY-04) 
    • Working voltage: 24VDC 
    • Measurement: 0~40Mpa 
    • Accuracy : ±0.25%FS/li>
    • Sensitivity:  0.25%FSnbsp;
    • Error: ±2%FSnbsp;
    • Output signal: 4~20Ma(2 wire) 
    • Working temperature: -55~ 100
    • Casing pressure sensor(CPS-TY-05) 
    • Working voltage: 24VDC 
    • Measurement: 0~110Mpa
    • Accuracy : ±0.25%FS/li>
    • Sensitivity:  0.25%FS/li>
    • Error: ±2%FSnbsp;
    • Output signal: 4~20Ma(2 wire) 
    • Working temperature: -45~ 70 3.7.7 Rotary speed sensor(CPS-BZ-02) 
    • P F sensor 
    • Working voltage: 24VDC
    • Response distance ≤15mm 
    • Working frequency <200HZ
    • Measurement: 0~400r /min 
    • Accuracy : ±0.25%FSnbsp;
    • Error: ±1r
    • Output signal: pluse signal (2 wire),high level>3.5VDC,low level<0.75VDC 
    • Working temperature: -45~ 70 
    • Pump stroke sensor 
    • P F sensor 
    • Working voltage: 24VDC z
    • Response distance ≤15mm 
    • Working frequency <200HZ 
    • Measurement: 0~400r /min z
    • Accuracy : ±0.25%FSnbsp;
    • Error: ±1r 
    • Output signal: pluse signal (2 wire),high level>3.5VDC,low level<0.75VDC 
    • Working temperature: -45~ 70 3.7.9 Pit level sensor z Simens sensor
    • Working voltage: 24VDC 
    • Measurement: 0.25~5m
    • Accuracy : ±0.5%FS/li>
    • Output signal: 4~20Ma(2 wire)
    • Working temperature: -45~ 100 
    • Mud density and temperature in sensor(CPS-MDT) 
    • Working voltage: 24VDC 
    • Measurement: 0~3g/cm 3 
    •  Accuracy: ±0.01%FS/li>
    • Sensitivity: 0.01g/cm 3 
    •  Output signal: 4~20mA(2 Wire) 
    • Working temperature: 0 ~ 125 
    • Working temperature for flange: 0 ~ 125 
    • Mud density and temperature out sensor 
    • Working voltage: 24VDC
    • Measurement: 0~3g/cm 3 
    •  Accuracy: ±0.01%FSnbsp;
    • Sensitivity: 0.01g/cm 3 
    • Output signal: 4~20mA(2 Wire)
    • Working temperature: 0 ~ 125
    • Working temperature for flange: 0 ~ 125 
    • Mud flowout sensor(CPS-CL-02) 
    • Working voltage: 24VDC 
    • Measurement: 0~100%&nsp;
    • Error: 5%&nsp;
    • Max angle: 45 o 
    • Output signal: 60Ω~800Ω 
    • Working temperature: -45~ 100 3.7.13 Mud Conductivity in sensor(CPS-DZ-06)
    • Working voltage: 24VDC 
    • Measurement: 300MS/cm 
    • Accuracy: ±1%FSnbsp;
    • Output signal: 4~20Ma(2 wire) 
    • Working temperature: 0 ~ 100 
    • Error: ±2%FSnbsp;
    • Mud Conductivity out sensor(CPS-DZ-06) 
    • Working voltage: 24VDC 
    • Measurement: 300MS/cm 
    • Accuracy: ±1%FS/li>
    • Output signal: 4~20Ma(2 wire) 
    • Working temperature: 0 ~ 100
    • Error: ±2%FS/li>
    • Geological Instrument   
    • Shale Density Kit Range : 2.15~2.85g/cm3 
    • Accuracy: 0.01g/cm3
    • Fluoroscope 
    • Wavelength: 350~365nm 
    • Power : >12W 
    • carbonate analyser 
    • working voltage: 220VAC
    • Meansurement: 0~100%
    • Error: ±2%FS/li>
    •  VMS
    • Working voltage: 220VAC 
    • Vacuum pressure: ≤-0.09Mpa 

    3.9 Signal system

    •  Simulation channels range 0~10V 
    • Simulation Channel accuracy <0.25%
    • Digital channel :  TTL
    • Digital channel error ±1bit

    3.10 Computer system 

    • System Hardware Hardware can adapt to the working conditions of the oil drilling site, choose a common software system compatible with the computer systems. Computer hardware configuration is as follows
    • Data collection computerstorage data serverengineering display disposal computerterra disposal computer and long-distance host computer
    • Printers 
    • Using TCP/IP networking connector                                                                                               

     Data server 

    • ∗ Appearance: MATX (142*334*369)
    • Processor: Intel Core Dou 
    • Memory ≥2G 
    • Hard disk ≥300G
    • DVD-ROM: DVD RW 
    • Display card: Nvidia PCI-E 6200TC-128M or higher 
    • Outside port: 1serial port 1parallel port PS2 USB2.0 Audio,3PCI 1PCI Express*16 
    • Logical mouse 
    •  LCD 
    • Special software

       Real-time server

    • Machine: MATX 142*334*369 
    • Processor: Intel Core Dou 
    •  Memory ≥2G ∗ Hard disk ≥300G 
    • DVD-ROM: DVD RW 
    • Display card:  Nvidia PCI-E 6200TC-128M or higher 
    • Outside port: 1serial port 1parallel port PS2 USB2.0 Audio,3PCI 1PCI Express*16

    Offline workstation 

    • ∗ Machine: MATX 142*334*369 
    • Type: P630 ∗
    • Memory ≥2G 
    • Hard disk ≥300G 
    • DVD-ROM: DVD RW 
    • Display card:  Nvidia PCI-E 6200TC-128M or higher
    • Outside port: 1serial port 1parallel port PS2 USB2.0 Audio,3PCI 1PCI Express*16

     Printer

    •  LaserJet printer HP1320 or equal 
    • EPSON LQ-1600KIIIH stylus printer or equal
    • EPSON Color printer 3500 COLOR or equal

    3.12.1.5 Repeater

    •  Geologist repeater 
    • Engineer repeater
    • Well platform EX-repeater

    Software deploy:

    • Windows 2000 
    • Office newest 
    • anti-virus software 
    • WELLSTAR® system software

     Software function 

    • Data collection system function Data Collection System, should be able to arbitrarily allocation and change their access, and easy expansion; Ensure continuous work in any conditions, Collecting real-time data storage and display; also meet the following main function.
    •  From signal processing system collection simulation and digital of signal 
    • Collecting and processing data from the rapid chromatography 
    • The status of conventional drilling data surveillance 
    • Real-time monitoring data records
    • Monitoring emerge wells
    • Monitoring pressure well 
    • Monitoring alarm parameter 
    • Datacurve real time output 
    • Engineering parameter abnormity of warn and monitoring 
    •  Monitoring time later fix well of issue
    • Long-distance monitoring 
    • Survey gas monitoring 
    • Mixed the number & letter of real-time data sent to the printer 
    • Through dynamic data exchange as network to provide real-time data workstations
    • Select to distance VGA monitor output 
    • Support signal is from all the different sensor input 
    • Timely or appropriate recording  ground and mud delayed system parameters, from the late-time detailed hole geometry calculated and constantly updated
    • Update the database

     

     Show data software function

    Well depthwell drilling pituprightness well depthdrill rig uprightness depthpower drill speedDC indexemendation move car speedHook LoadMax Hook Load only for data-base Max Hook Load depth only for data-base Average Hook Loadonly for data-base expectation Hook Loadsample of rock bits depthdrilling pressuretotal of drill plate rotate speedNo.1 total of Pump Stroke speedNo.2 total of Pump Stroke speedNo. 3 total of Pump Stroke speedtotal of stroke speed all pump  delay timesurround volumeMud Pitfor all mud pitonly for ordinary  expectation mud pitfor all decrease of ordinary mud pitmud pit cans equivalent circulating densitysuction / volatility drilling of time (drilling), the bit of time (designated eyes). has come drilling column quantity, have not drilling column quantity , maximum suction / pump pressure fluctuations depth (only for the database) Minimum suction / pump pressure fluctuations (only for the database), the smallest of suction / pump pressure fluctuations depth 

    Offline program function

    • To provide optimization of drilling parameter and real-time interpretation geological data
    • users can use their own software connection
    • the results can produce all types of charts and reports
    • User-definable lithology and other annotation
    • under the Windows menu can automatically lithology descriptions without manual input 
    • All of the graphics and the use of the International System of Units can print information. the system can also be converted to meters and inch 
    • gas interpretation 
    • water-powered computing
    • drill costs 
    • Directional Well service 
    • Hole structure
    • Press well program 
    • suction / volatility 
    • Cementing
    • Ton*kilometers program
    • Evaluation of formation pressure / fracture pressure gradient

    Chromatogram system hard disk 

    • Host computer:  at lest CPU486
    • Hard disk typeCF card over 4G
    • Memery: no less than 256M
    • Display: 8 1/4”LCD 480×640
    • Pellicle keyboard

     Chromatogram software

    • WINXP operation system
    • CPSIC’s Chromatogram software system

     Software function

    • Data collection disposaldisplay transform save and print function 
    •  Draw displaysave and print function
    • Zoom inZoom outmobilerepeat function 
    • Show TH voltage valueconsistence value 
    • Display GH of voltage and consistence value
    • Display H 2AIRSample gaspressure value
    • Show temperature value
    • Curve regression function

    Seller Terms

    • Salvex and the seller have the right to reject any and all offers.
    • This product is sold AS IS, WHERE IS.
    • Buyer is responsible for all taxes, duties, loading and freight charges.
    • Seller does not offer any warranties or manufacturer warranties.
    • Upon receipt of cleared funds, Seller will provide the Buyer a Release Order for item pick up. Title transfers from Seller to Buyer upon issuance of the Release Order.
    • It is Buyer's responsibility to verify quantities and condition at the time of pick up. Once the product has been removed from Seller's location, there will be no adjustments based on quantity or condition.

    Salvex is a prominent global e-commerce platform specializing in the sale of surplus commercial assets. We collaborate with thousands of companies, both publicly traded and private, spanning 200 countries worldwide. Our expertise lies in repurposing Oil and Gas and Well Equipment sourced from insurance claims, corporate surpluses, asset recoveries, bankruptcies, and natural disasters. We identify markets across North America, South America, Europe, Africa, the Middle East, Asia, and Oceania. Through our global sustainability initiatives, we contribute to environmental preservation by implementing carbon offset strategies through asset repurposing. We look forward to assisting your company in finding exceptional deals by showcasing surplus assets that align with your requirements.

    Salvex handles surplus, bankruptcy, overruns, obsolete inventory, disposal, insurance claims, online auctions, liquidation sale, foreclosure, lockout, seized, scrap, salvage, new, used, damaged, refurbished, and asset recovery.

    Repurposing commercial assets creates carbon offsets and sustainability corporate solutions.