10 Offshore Living Quarters Modules

CLOSED - This listing is closed and no longer available for sale. To see active listings click here.
View Active Listings
Register As a Buyer 
ID: 182938794
Quantity: 10 Modular Units
Condition: According to the seller: "These are brand new unused (2 have been used for a short period) high spec." They are no longer needed for the purpose that they were aquired.
# of Bids: 0
Product Location: Stavanger, International, Norway
End Time: Dec-02-09 01:00 PM CST
Time Remaining: closed
Market Maker: Tim Nguyen   713-229-9000 x111

Seller Terms

  • This product is sold AS IS, WHERE IS.
  • Buyer is responsible for all taxes, duties, loading and freight charges.
  • Seller does not offer any warranties or manufacturer warranties.
  • Upon receipt of cleared funds, Seller will provide the Buyer a Release Order for item pick up. Title transfers from Seller to Buyer upon issuance of the Release Order.
  • It is Buyer’s responsibility to verify quantities and condition at the time of pick up. Once the product has been removed from Seller’s location, there will be no adjustments based on quantity or condition.
Location shown on the map is in the general vicinity of the actual location.
Offshore Accommodation Units for Sale. Seller is disposing of living quarters. According to the seller: "These are brand new unused (2 have been used for a short period) high spec."

Living Quarters Modules.

  • Included are ten accommodation units each consisting of 4 single berth cabins with Wet Unit facilities and one Locker Unit catering for 40 personnel.

    Additional Living Quarters Technical Specification

    Details:
  • Fully certified temporary accommodation containerized units.
  • The cabin configuration shall be Single cabin occupancy with associated locker room facilities for the full compliment of 40 personnel. Configured in 1 block complete with locker room.
  • 40 beds (single person occupancy).

    Locker Room facilities
  • 40 lockers with bench seating in front
  • Toilet & Washing facilities (No Showers). General
  • All Lifting Sling arrangements include full certification
  • All systems shall be self contained as much as is practical.
  • The offshore hook-up scope will be minimised.

    Weight Lifting Limitation
  • The modules, including lifting rigging, shall not exceed the Platform crane maximum lift capability.

    Layout/Dimensions
  • The following layout and dimensional criteria is applicable to the ALQ:
  • Module height should not exceed 3,5m, preferably be below 3,2m
  • Plot for modules approx. 13m x 13m – preferred entrances east and west side of modules positioned beneath the Heli Deck
  • Internal Seafastening
  • As-built documentation.
  • Operation and Maintenance documentation

    Construction
  • Fire Protection
  • Rated Bulkheads – A60
  • Cladding Method: Profile Plate with 3mm dia x 85mm long fixing pins stud welded on troughs at 300mm max horizontal and vertical centres.
  • A weld mesh 1 inch square pre-galvanised sheet secured with speed fix washers applied over studs.
  • A layer of 75mm thick “Rockwool Firebatt 2000” 100kg/m3 density applied over mesh. Aluminium Foil vapour barrier applied over insulation with all joints sealed using aluminium foil backed tape and all pin penetrations mastic sealed.
  • A layer of half inch hexagonal wire mesh insulation retainer placed over fixing pins and secured using speed fix washers. Joints in wire mesh lapped 50mm min over fixing pins.
  • Rated Roof / Frame – A60
  • Cladding Method: Roof Plate with 3mm dia x 85mm long fixing pins stud welded on troughs at 300mm max horizontal and vertical centres. 3mm dia x 35mm long fixing pins welded onto trapezoidal stiffeners at 300mm max vertical centres. 3mm dia x 60mm long fixing pins welded onto the inside face trapezoidal stiffeners at 300mm max vertical cenbtres. A layer of 75mm thick “Rockwool Firebatt 2000” 100kg/m3 density applied. Troughs packed with 50mm “Rockwool Firebatt 2000” 100kg/m3 density. Aluminium Foil vapour barrier applied over insulation with all joints sealed using aluminium foil backed tape and all pin penetrations mastic sealed. A layer of half inch hexagonal wire mesh insulation retainer placed over fixing pins and secured using speed fix washers. Joints in wire mesh lapped 50mm min over fixing pins.
  • Rated Deck – A60
  • Cladding Method: Deck Plate with 3mm dia x 85mm long fixing pins stud welded on troughs at 300mm max horizontal and vertical centres. 3mm dia x 35mm long fixing pins welded onto trapezoidal stiffeners at 300mm max vertical centres. 3mm dia x 60mm long fixing pins welded onto the inside face trapezoidal stiffeners at 300mm max vertical cenbtres. A layer of 75mm thick “Rockwool Firebatt 2000” 100kg/m3 density applied. Troughs packed with 50mm “Rockwool Firebatt 2000” 100kg/m3 density. Aluminium Foil vapour barrier applied over insulation with all joints sealed using aluminium foil backed tape and all pin penetrations mastic sealed. A layer of half inch hexagonal wire mesh insulation retainer placed over fixing pins and secured using speed fix washers. Joints in wire mesh lapped 50mm min over fixing pins.
  • Reference Documents: QP-MG-N-0028

    Painting & Coatings
  • All Painting and coatings are as per BPN-M-501 rev 04 Additional Requirements to NORSOK Standard M-501.

    External Doors
  • All McGeoch A60 Hinged painted doors c/w vision panel with Bolted Frame.

    External Escape Hatches All McGeoch A60 Hinged painted Hatches with Bolted Frame.

    Internal Doors
  • Cabin Doors - All Momec B30 Hinged 40db noise reduction finished in Isolamin M27 Foil.
  • Corridor Doors - All Momec B15 Hinged 30db noise reduction c/w Vision Panel, finished in Isolamin M27 Foil
  • Wet Unit Doors - All Momec B15 Hinged 30db noise reduction finished in Isolamin M27 Foil
  • Internal Wall Panels All Isolamin C-Clip B15 40db Wall Panels finished in Isolamin M27 Foil.
  • Lockers in Locker Area 40 no. 1800mm x 300mm x 450mm single tier work locker from Elite Lockers in powder coated steel – Grey carcass with Blue Doors, c/w bench seating.

    Cabin Furniture
  • All cabin furniture constructed using FR Core MDF and FR Laminate.

    Piping and Mechanical
  • All Piping material within the ALQ modules are low pressure washroom related piping equipment connected to the Wet Rooms. Details can be reviewed on relevant
  • Piping drawings and arrangements. Reference Documents: QP-MG-L-0002, QP-MG-L-0004-001
  • The ALQ does not require a Sprinkler System.

    Electrical
  • Cable Types Utilised: Draka
  • External Power / Lighting Cables – NEK 606 Code P5/P12 BFOU 0.6/1kV
  • Internal Power / Lighting Cables – NEK 606 Code P17 BU 0.6/1kV
  • Earthing Cable – NEK 606 P15 UK 1000V
  • External Junction Boxes:
  • Technor EEXe 11 T4-6 IP66
  • Internal Light Fittings:
  • Ceiling Lights – Glamox 300 x 600mm recessed 1 x 18W 230V
  • Ceiling Lights – Glamox 300 x 600mm recessed 2 x 18W
  • Bunk Lights – Glamox 230V All Cable drops encased in “Adaptaflex” Super Low Fire Hazard PK standard weight Peek Conduit.
  • Due to platform specific operational requirements all power to control systems is designed to come from separate supply within the main platform system. The modules are therefore not stand alone units and require tie ins to the main platform systems for all controls.

    Instrumentation
  • Cable Types Utilised: Draka
  • External Comms / PA / F&G – NEK 606 Code S3/S7 BFOU(i) 250V
  • Internal Comms / PA / F&G – NEK 606 Code S13 BU(i) 250V
  • External Junction Boxes:
  • Technor EEXe 11 T4-6 IP66

    Smoke Detection:
  • Autronica Optical 24Vdc

    Heating, Ventilation and Air Conditioning
  • 4 man Accommodation Module
  • The HVAC System serving the accommodation modules comprises of the following:
  • Common Fresh Air Pressurisation Unit
  • Inlet louvre
  • Filter Section
  • Centrifugal Fan Direct Drive
  • Flame Proof Drive Motor
  • Fan Discharge Duct
  • Supply A60 Fire Damper
  • A60 Spool Piece
  • Ambient Duct heater T3
  • Spiral Wound Attenuator
  • Spiral Wound Galvanised Distribution Ductwork
  • Volume Control Balancing Dampers
  • Cabin Terminal Re-Heat Units – 1 per Cabin
  • Split System Air Conditioning – Cool Only – 1 per Cabin
  • Air Transfer System c/w Cross Talk Attenuators – 1 per Cabin.
  • Toilet Extract system
  • Exhaust louvre Stainless Steel
  • Exhaust A60 Fire Damper
  • A60 Spool Piece
  • Centrifugal Exhaust Fan (inline)
  • Spiral Wound Sound Attenuator
  • Spiral Wound Galvanised Exhaust Ductwork
  • Volume Control Balancing Dampers
  • Exhaust Valves Exhaust Grilles
  • HVAC Control Panel
  • HVAC Operating Philosophy

    Cabin Modules
    External to the accommodation modules is a plant recess. Located within this plant recess are the 4 no. Condensing Units and the Pressurisation Fan Unit complete with external ductwork. The pressurization unit is mounted on a stainless steel subframe on anti-vibration mounts. The Stainless Steel supply ductwork rises and connects to the supply air penetration located near the top of the plant recess. At the internal side of the supply penetration is bolted an A60 fire damper, A60 Spool, ambient duct heater and then the distribution ductwork serving the four one man cabins. The ambient duct heater is designed to pre-heat the ambient air during heating periods and supply air at a temperature in the region of 16 deg C to the terminal re-heater units. Each cabin has a terminal re-heater unit complete with constant volume valve and perforated supply grille. The 500watt stab in heater mounted in the terminal unit is wired to a wall mounted thermostat to give the occupant individual control of the cabin temperature. During summer months if cooling is required the occupant in each cabin has a high level wall mounted split system air conditioning unit providing cool only operation. The ventilation supply to the module is 100% full fresh air providing ventilation for the occupants and pressurization to the module to provide an internal positive pressure with resect to atmosphere. Each cabin is served with fresh, filtered, tempered air that can be re-heated to suit the occupant. Air is transferred under the positive pressure to the high level transfer grille located between the cabin and cabin corridor. Each Cabin has a high level transfer system which incorporates a cross talk attenuator to prevent any noise transmission to and from the cabins. The cabin air when transferred to the corridor is extracted via the corridor extract grille. The toilet extract system serves both wet areas and also the cabin corridor and consists of a duct mounted inline centrifugal fan, attenuators, fire dampers, distribution ductwork and exhaust grilles. The entrance area of the module has a supply diffuser to maintain positive pressure with respect to atmosphere and is balanced with the extraction rate of the two wet units.

    Locker Module
    The locker module as with the accommodation module is served by 100% fresh air providing ventilation and odour removal for the occupants and positive pressure with respect to atmosphere. The Locker Module is served by a similar HVAC system to the accommodation modules but this time only two split system air conditioning systems are installed, but larger capacity than thoise installed in the cabins. The main duct mounted heater provides heating in winter with the temperature sensor located in the exhaust air to provide better temperature control for the whole space. The toilet extract system is similar in layout to the accommodation modules with duct mounted inline centrifugal fan, attenuators, fire dampers, distribution ductwork and exhaust grilles. There is a small extract valve fitted in the cleaners cupboard connect to the toilet extract system.
  • HVAC Control Panel
  • Each module has a basic HVAC control panel controlling the temperature control for ambient duct heater, fire dampers, heater interlocks and F&G interlock. The power for the pressurization fan and ambient duct heater are provided by switchboards located within the main Living Quarters Module. The HVAC panel only supplies enable / disable signals to the switchboard and does not have any 3 phase supplies within. The terminal re-heaters and toilet extract are fed directly from the ALQ distribution Boards and are not interlocked with the ALQ HVAC Control Panel.

    LIFTING & WEIGHING
  • Weighing
  • Weight and Centre of Gravity Calculations and test results for each module are available for review. Project Document reference: QP-MG-N-0016.
  • Lifting Equipment
  • Lifting Slings and separate Spreader Beam Arrangement are available. Current Certification to be checked and validated by new owner. Reference Documents: QP-MG-R-0011 and QP-MG-R-0012

    MECHANICAL COMPLETION AND COMMISSIONING
  • Mechanical Completion
  • Modules reached Mechanical Completion with all sign offs according to the Project Specific GoCCMs system. Data books available for inspection.